Fluoroplastic Needle Valves

High-Precision Fluoroplastic Needle Valves - Corrosion & High-Temperature Resistant Fluid Control Expert
Detail

Product Overview

AOKAVI fluoroplastic needle valves are manufactured using advanced PTFE, PFA, and PVDF materials, specifically designed for highly corrosive media and ultra-high purity applications. Featuring precision-machined fine-thread structures, they enable micron-level flow regulation, meeting the most demanding industrial process control requirements.

Product Structure and Advantages

(I) Core Structure Breakdown

Valve Body: Integrally injection molded, no weld seams, preventing corrosive media penetration; smooth inner wall (Roughness Ra ≤ 0.8μm) reduces fluid retention and contamination risk.

Valve Core & Stem:

Valve Core: Precision-turned from fluoroplastic, cone surface and valve seat contact ratio reaches 99.5%, achieving zero-drip sealing.

Valve Stem: PTFE-clad design, paired with reinforced PTFE sealing packing, balances sealing performance and smooth operation, preventing stem seizure caused by corrosion.

Sealing Components: Use full-fluoropolymer O-rings (PTFE/PFA), replacing traditional rubber seals, no aging, no leaching, compatible with various corrosive media.

Adjustment Knob: Non-slip texture design, with scale markings (0-10 grades), for precise flow control and convenient operation.

(II) Structural Advantages

Zero Contamination Design: All wetted parts are fluoroplastic, no metal ion leaching, meeting electronic-grade and pharmaceutical-grade fluid purity requirements.

Corrosion Resistance Upgrade: 100% fluoroplastic coverage from body to seals, completely solving the corrosion failure problem of metal valves (stainless steel, Hastelloy) in strong corrosive environments.

Long Life Assurance: Fluoroplastic materials resist aging and fatigue, with a service life exceeding 8,000 open-close cycles under normal conditions, 3-5 times that of traditional metal valves.

Technical Parameters

Technical Parameter Category

Unit

PTFE

PFA

PVDF

I. Basic Specifications

-

-

-

-

Nominal Diameter (DN)

mm/inch

DN2~DN25 (1/8"~1")

DN2~DN25 (1/8"~1")

DN2~DN25 (1/8"~1")

Nominal Pressure (PN)

MPa

0.6~1.6 @RT (Reduces to 0.3 @260°C)

0.6~1.6 @RT (Maintains 0.8 @260°C)

1.0~2.0 @RT (Reduces to 0.6 @150°C)

Connection Type

-

Internal Thread (NPT/BSPT), Ferrule, Flange

Internal Thread (NPT/BSPT), Ferrule, Flange

Internal Thread (NPT/BSPT), Ferrule, Flange

II. Core Performance

-

-

-

-

Temperature Range (Continuous Use)

°C

-200~260 (Short-term up to 300)

-200~260 (No performance degradation)

-40~150 (Long-term use max)

Leak Rate (He Test)

mL/min

≤1×10⁻⁶ (25°C, 1MPa)

≤5×10⁻⁷ (25°C, 1MPa, Better Sealing)

≤1×10⁻⁶ (25°C, 1MPa)

Body Roughness (Ra)

μm

≤0.8 (Smooth inner wall)

≤0.4 (Smoother inner wall, lower fluid retention)

≤0.8 (Smooth inner wall)

Operating Torque

N·m

5~12 (Depends on size, @RT)

4~10 (Depends on size, good toughness, lower torque)

6~14 (Depends on size, high rigidity, slightly higher torque)

III. High-Temp Creep Performance

-

-

-

-

150°C/10MPa Creep Rate (1000h)

%

8.5~10.2 (Significant creep, control long-term load)

5.2~6.8 (Low creep rate, excellent structural stability)

2.1~3.5 (Lowest creep rate, strong high-temp rigidity)

200°C/5MPa Creep Rate (1000h)

%

12.3~14.5 (Creep intensifies at high temp)

7.8~9.3 (Controlled creep, suits medium-high loads)

N/A for this temp (Exceeds long-term temp limit)

260°C/2MPa Creep Rate (1000h)

%

18.6~21.4 (Significant creep under high temp, low load)

10.5~12.8 (Optimal high-temp stability, lowest creep)

N/A for this temp (Exceeds long-term temp limit)

IV. Material Properties

-

-

-

-

Corrosion Resistance

-

Resists almost all chemicals (except molten alkali metals)

Same as PTFE, better permeability resistance than PTFE

Resists strong acids/alkalis/organic solvents, strong weatherability

Leachables/Extractables

μg/cm²

<0.1 (Low, meets high cleanliness)

<0.05 (Ultra-low, suits electronic/pharma)

<0.2 (Low, meets general cleanliness)

Mechanical Strength (Tensile)

MPa

20~25 (Medium hardness, good creep resist)

22~28 (Toughness > PTFE, good impact resist)

35~45 (Highest strength, optimal rigidity/wear resist)

Service Life (Open-Close Cycles)

cycles

≥8000 (Normal conditions)

≥10000 (Normal conditions, better fatigue resist)

≥9000 (Normal conditions, wear resistance supports long life)

V. Compliance & Compatibility

-

-

-

-

Certification Standards


ISO 9001 & Related Standards



Applicable Fluids

-

High-temp corrosive fluids, lab reagents, general high-cleanliness fluids

Electronic-grade chemicals, pharmaceutical sterile fluids, ultra-high temp fluids

Chemical process fluids, environmental wastewater, seawater, medium-temp corrosive fluids

Application Scenarios

(I) Industry Scenario Display

Chemical Industry: Used for feeding/discharge control in strong acid/alkali reactors, replacing stainless steel valves to avoid media leakage and equipment damage caused by corrosion.

Semiconductor Industry: Suitable for electronic-grade hydrofluoric acid, photoresist, and other high-purity fluids; low extractables ensure wafer processing yield.

Pharmaceutical Industry: Complies with GMP standards, used for transfer and regulation of sterile liquids and corrosive disinfectants; no leachables contaminate the liquid.

Environmental Protection Industry: Handles wastewater containing heavy metal ions and strong oxidizers; strong weatherability suits outdoor or harsh environment installation.

Laboratory/Research Fields: Miniaturized specifications (DN2~DN6) suit micro-corrosive fluid experiments in labs, enabling precise flow control.

(II) Scenario Solution Example
Problem: A semiconductor factory used stainless steel needle valves for electronic-grade hydrofluoric acid. Internal leakage occurred after 3 months, leading to pipeline corrosion by hydrofluoric acid, resulting in high maintenance costs and production impact.
Solution: Replaced with this PFA material needle valve. Full fluoroplastic material resists hydrofluoric acid corrosion, no metal leaching. After installation, it operated continuously for 18 months without leakage, reducing equipment maintenance costs by 70%.

Selection Guide

(I) Material Selection Advice

Prioritize Temperature Needs:

Temperature >150°C or <-40°C: Choose PTFE or PFA.

Temperature ≤150°C and ≥-40°C: PVDF can be chosen (lower cost, higher strength).

Then Consider Cleanliness Requirements:

Semiconductor, pharmaceutical sterile scenarios: Choose PFA (ultra-low extractables).

General chemical, environmental scenarios: PTFE or PVDF are both suitable.

Finally Consider Mechanical Strength:

Frequent operation, high wear resistance required: Choose PVDF.

Low-frequency operation, high-temperature scenarios: Choose PTFE/PFA.

(II) Specification Selection Steps

Determine Nominal Diameter (DN): Based on pipeline flow requirements, refer to correspondences like "DN2 (Flow ≤0.5m³/h), DN6 (Flow ≤2m³/h), DN15 (Flow ≤10m³/h)".

Determine Connection Method:

Small diameter (DN2~DN10): Prefer ferrule connections (easy installation, good seal).

Large diameter (DN15~DN25): Choose threaded or flange connections (high stability).

Confirm Nominal Pressure: Select the corresponding PN rating based on the pipeline system pressure.

(III) Selection Table (Simplified)

Application Scenario

Recommended Material

Recommended Spec (DN)

Connection Method

Semiconductor Electronic Fluid

PFA

DN2~DN10

Ferrule

Pharmaceutical Sterile Liquid

PFA/PTFE

DN6~DN15

Ferrule / Flange

Chemical Strong Corrosive Fluid

PTFE/PVDF

DN10~DN25

Thread / Flange

Environmental Wastewater

PVDF

DN15~DN25

Flange

Laboratory Micro Fluid

PTFE

DN2~DN6

Ferrule

Frequently Asked Questions (FAQ)

1. Q: Is the corrosion resistance of fluoroplastic needle valves really better than metal valves?
A: Yes. Fluoroplastics (especially PTFE/PFA) have far superior tolerance to strong acids, alkalis, and organic solvents than metals like stainless steel (304/316L) and Hastelloy. For example, in 50% concentrated nitric acid, PTFE shows no corrosion, while 316L stainless steel shows significant rust within 24 hours. Therefore, fluoroplastic valves are the only reliable choice for strong corrosion scenarios.

2. Q: Is the operating torque for fluoroplastic valves very high? Will they become hard to turn?
A: No. Our valve stem uses a "PTFE-clad + reinforced packing" design, reducing operating torque to only 60% of traditional fluoroplastic valves. Torque does not increase significantly with use. Additionally, the precision-lapped valve core and seat prevent sticking, allowing easy manual operation under normal conditions.

3. Q: Can fluoroplastic valves be adapted with pneumatic or electric actuators?
A: Yes. We provide custom valves with actuator mounting interfaces, compatible with mainstream pneumatic (single/double acting) and electric actuators to meet automation control needs. Please contact customer service for specific customization solutions.

MORE REQUEST TO MEET?
SEND US AN EMAIL
TALK WITH OUR SALES
● Valves
swu@aokavi.com
Contact Us
.
*
.
*
.
*
.
*
.
*
Send Message
Keep Up On Our Always Evolving Product Features& Technology.
Enter Your E-mail Address & Subscribe
To Us.
️ ️    Company:
Shanghai Aokavi Industrial Co.,Ltd.
    Address:
No. 309, Changshou Road, Putuo District, Shanghai.

    E-mail:
swu@aokavi.com
    Contact Num:
86-15000356886